Actual Certified Material Test Report

Alloy

ERCu (AWS A5.7)

Diameter

1/16"

Heat Number

045025

Date Entered

8/3/2004

Entered By

JLA

CHEMICAL ANALYSIS:

Aluminum (Al)

0.01

Copper (Cu)

BAL

Lead (Pb)

0.01

Manganese (Mn)

0.42

Phosphorus (P)

0.026

Silicon (Si)

0.38

Tin (Sn)

0.67

Typical Certified Material Test Report

Alloy

ERCu (AWS A5.7)

Date Entered

9/10/2012

Entered By

BY

CHEMICAL ANALYSIS:
(Single values are maximum)

Aluminum (Al)

0.01

Copper (Cu)

(including Ag) 98.0 min

Lead (Pb)

0.02

Manganese (Mn)

0.50

Phosphorus (P)

0.15

Silicon (Si)

0.50

Tin (Sn)

1.0

Chemical Other

0.50

MELTING POINT 1967 DEGREES F

TENSILE STRENGTH, ksi: 25 YEILD STRENGTH, ksi: 8

% ELONGATION min: 25

Welding Material Sales certifies that the above chemical test results are correct and conform to the AWS specification stated as contained in the records of the company. The test report represents the actual attributes of the heat number furnished.

Brian W. DePaul