Actual Certified Material Test Report

Alloy

ER316LSI (AWS A5.9)

Diameter

1/16"

Heat Number

V2661

Date Entered

9/7/2004

Entered By

JLA

CHEMICAL ANALYSIS:

Carbon (C)

0.0230

Chromium (Cr)

18.0500

Copper (Cu)

0.1300

Manganese (Mn)

1.7700

Molybdenum (Mo)

2.6000

Nickel (Ni)

12.0300

Nitrogen (N)

0.0490

Phosphorus (P)

0.0230

Silicon (Si)

0.7600

Sulfur (S)

0.0010

Typical Certified Material Test Report

Alloy

ER316LSI (AWS A5.9)

Date Entered

9/10/2012

Entered By

BY

CHEMICAL ANALYSIS:
(Single values are maximum)

Carbon (C)

0.03

Chromium (Cr)

18.0-20.0

Copper (Cu)

0.75

Manganese (Mn)

1.0-2.5

Molybdenum (Mo)

2.0-3.0

Nickel (Ni)

11.0-14.0

Phosphorus (P)

0.03

Silicon (Si)

0.65-1.00

Sulfur (S)

0.03

YIELD STRENGTH, ksi: 64

TENSILE STRENGTH, ksi: 90

% ELONGATION min: 37

Welding Material Sales certifies that the above chemical test results are correct and conform to the AWS specification stated as contained in the records of the company. The test report represents the actual attributes of the heat number furnished.

Brian W. DePaul